CMS-50QA Pediatric Fingertip Pulse Oximeter with Alarm
Have a question?
The CMS50QA Pediatric Finger Pulse Oximeter was designed from the ground up to be suitable for children. From the designers of the popular adult finger pulse oximeters CMS 50B and 50E comes the latest offering from Contec Medical Systems. These specially designed oximeters detect both pulse rate and blood oxygen saturation level (SPO2).
The CMS50QA manufacturing uses a small-footprint process that includes a new software algorithm and sensor made with the physical parameters for children. The calibrated sensor measures the thinner skin surface of children, whose skin could be as little as 0.3 inches (8mm). This monitor is recommended for use on children ages 2 to 13, with a minimum body weight of 35 lbs (16 kg). The bright LCD allows for easy viewing with high contrast.
- CMS-50QA Pediatric Finger Pulse Oximeter Unit (LCD)
- Rechargeable Battery (Installed) with USB PC/wall charger
- Neck/Wrist cord
- Instruction manual
- Ergonomic design without sharp edges to help avoid injury to the child
- LCD display with multiple display modes
- Heart beat displayed as bar graph or wave form
- Auditory alarm for when readings exceed preset specifications
- Heart beat tracking sound
- Indicator for low power
- Automatic shut-off for when no finger is detected
Why choose the CMS-50QA?
The most innovative feature of this product is its built-in heartbeat tracker. This auditory blip helps keep track of heartbeat measurements without requiring the user to look at the display visually. Also included is an audio alarm that would detect when heart rate or SpO2 exceeds a preset specification.
Sized for Children
The blood oxygen monitor opening where users insert their finger is miniaturized and suited for pediatric care or pediatric nursing. This child-sized sensor also helps prevent ambient light from entering the orifice that could cause inaccuracies in the reading.
SpO2 Range: 0% ~ 99% |
SpO2 Accuracy: When the SpO2 measuring range is 70% ~ 99%, the permission of absolute error is ±2%; Below 70% unspecified |
SpO2 Resolution: 1% |
Pulse Rate Range: 30bpm ~ 250bpm |
Pulse Rate Accuracy: ±2bpm or ±2% (select larger) |
Pulse Rate Resolution: 1bpm |
Power Supply Requirement: 3.6V DC ~ 4.2V DC Rechargeable Battery |
Measurement Performance in Weak Filling Condition: SpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%. SpO2 error is ±4%, pulse rate error is ±2bpm or ±2% |
Resistance to Surrounding Light: The deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than ±1% |